mcDSA-E42

Articlenumber: 1504954


mcDSA-E42
Motor controller up to 30 A
Compact four-quadrant controller for BLDC motors, DC motors, Linear motors
CAN Interface (protocol DS301, Device profile DS402)
integrated digital inputs
integrated digital outputs
integrated analog inputs
Overvoltage, undervoltage and overtemperature monitoring
Device status notification with the help of 3 LEDs (Power, Status, Error)
Hex switches to set the device node id
Easily programmable due to built-in MPU (Motion Process Unit)
NameValue
Supply voltages
     Electronic current consumption@ Ue=24V250 mA
     Electronic supply voltage Ue19 .. 30 V
     Power supply voltage Up39 .. 60 V
    
Output current
     Continuous output current @ Up=24V410 A
     Continuous output current @ Up=48V48.5 A
     Max. output current30 A
    
PWM
     Output voltage90% Up
     PWM frequency25, 325, 50 kHz
     PWM modesymmetrical / asymmetrical
    
Motor types
     BLDC motorsyes
     DC motorsyes
     Linear motorsyes
     Stepper motorsno
    
Mechanical
     AssemblyTop-hat rail / Wall
     ConnectorsTension clamp connection
     Size LxWxH110 x 23 x 77 mm
     Weight110 g
    
CAN bus
     Galvanically isolatedno
     CAN specification2.0B
     Max. baudrate1 Mbit/s
     Device profileDS402
     ProtocolDS301
    
Encoder
     Input voltage1 V
     Resolution13 bit per sine period
     Signals+SIN,-SIN,+COS,-COS
     Signal typeSIN/COS, analog, differential
     TypeSIN/COS
    
Digital inputs
     High voltage6 .. 30 V
     Low voltage-30 .. 5 V
     Number4 (Din0..3)
    
Digital outputs
     Continuous output current1.5 A
     Loadresistive, inductive
     Number1 (Dout0)
     Output voltageElectronic supply voltage Ue
     Signal typepositive switching
    
Analog inputs
     Number1 (Ain0)
     Signal type0..10 V, 12 Bit, single ended
1No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
2power amplifier switched off, 5V output (sensor supply) is free
3No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
4connector cable with max. possible cable cross-section, PWM frequency 32 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 10 A → 8.2 Aeff, 8.5 A → 6.9 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
5default value
6Hex-Switches should be not used at T < -25°C (setting of node ID only possible by firmware parameters)
mcManual 🔒
2D/3D-Drawing 🔒
mcPLC 🔒