mcDSA-F50-HC

Articlenumber: 1514122

Certifications:


mcDSA-F50-HC
Motor controller up to 25 A
Compact four-quadrant controller for BLDC motors, Linear motors
CAN Interface (protocol DS301, Device profile DS402)
integrated digital inputs
integrated digital outputs
integrated analog inputs
Overvoltage, undervoltage and overtemperature monitoring
Device status notification with the help of 3 LEDs (Power, Status, Error)
Hex switches to set the device node id
Easily programmable due to built-in MPU (Motion Process Unit)
NameValue
Supply voltages
     Electronic current consumption@ Ue=24V260 mA
     Electronic supply voltage Ue19 .. 30 V
     Power supply voltage Up39 .. 60 V
    
Output current
     Continuous output current (not certified)5
@Up ≤ 24V
@Up ≤ 48V

14.5 A
14.5 A
     Continuous output current (certified UL)4
@Up ≤ 24V
@Up ≤ 60V

9.5 A
9.0 A
     Max. output current25 A
    
PWM
     Commutation typeField Oriented Control
     PWM frequency32 kHz
     PWM modeSVPWM
    
Motor types
     BLDC motorsyes
     DC motorsno
     Linear motorsyes
     Stepper motorsno
    
Mechanical
     AssemblyWall
     ConnectorsTension clamp connection, crimp technology
     Size LxWxH87 x 74 x 29 mm
     Weight95 g
    
CAN bus
     Galvanically isolatedyes
     CAN specification2.0B
     Max. baudrate1 Mbit/s
     Device profileDS402
     ProtocolDS301
    
Sensor supply (Encoder/Hall)
     Max. output current0.2 A
     Output voltage5 V
    
Incremental encoder
     Input voltage (24V tolerant)0 .. 5 V
     Max. freqency (per channel)500 kHz
     SignalsA,/A,B,/B,Inx
     Signal typedifferential, open collector, single ended
     Typeincremental
    
Hall sensors
     Input voltage0 .. 5 V
     Max. freqency (per channel)10 kHz
     SignalsH1,H2,H3
     Signal typeopen collector, single ended
    
Digital inputs
     High voltage8 .. 30 V
     Low voltage0 .. 5 V
     Number - digital inputs8 (Din0..7)
    
Digital outputs
     Continuous output current (certified UL)0.3 A
     Loadresistive, inductive
     Number4 (Dout0..3)
     Output voltageElectronic supply voltage Ue
     Signal typepositive switching
    
Analog inputs
     Number3 (Ain0..2)
     Signal type - Ain2 / PT10000..5 V, 12 Bit, single ended / PT1000
1No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
2power amplifier switched off, 5V output (sensor supply) is free
3No reverse polarity protection, the destruction limit is at overvoltage of >= 70V
4connector cable with max. possible cable cross-section, PWM frequency 32 kHz (SVPWM), ambient temperature 40 °C, I/O's and 5V output active, RMS current: 9.5 A → 6.7 Aeff, 9.0 A → 6.4 Aeff
5connector cable with max. possible cable cross-section, PWM frequency 32 kHz (SVPWM), ambient temperature 40 °C, I/O's and 5V output free, RMS current: 14.5 A → 10.3 Aeff, 14.5 A → 10.3 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
6Hex-Switches should be not used at T < -25°C (setting of node ID only possible by firmware parameters)
7default value
mcManual 🔒
2D/3D-Drawing 🔒