mcDSA-S65-Modul

Articlenumber: 1506122


mcDSA-S65-Modul
Motor controller up to 10 A
Compact four-quadrant controller for Stepper motors
CAN Interface (protocol DS301, Device profile DS402)
integrated digital inputs
integrated digital outputs
integrated analog inputs
Overvoltage, undervoltage and overtemperature monitoring
Device status notification with the help of 3 LEDs (Power, Status, Error)
Easily programmable due to built-in MPU (Motion Process Unit)
NameValue
Supply voltages
     Electronic current consumption@ Ue=24V235 mA
     Electronic supply voltage Ue19 .. 30 V
     Power supply voltage Up39 .. 60 V
    
Output current
     Continuous output current @ Up=24V43.5 A
     Continuous output current @ Up=48V53 A
     Max. output current10 A
    
PWM
     Output voltage85% Up
     PWM frequency25, 32, 506 kHz
     PWM modesymmetrical
    
Motor types
     BLDC motorsno
     DC motorsno
     Linear motorsno
     Stepper motorsyes
    
Mechanical
     AssemblyBackplane
     ConnectorsPin header
     Size LxWxH53 x 41 x 10 mm
     Weight18 g
    
CAN bus
     Galvanically isolatedno
     CAN specification2.0B
     Max. baudrate1 Mbit/s
     Device profileDS402
     ProtocolDS301
    
Incremental encoder
     Input voltage5 V
     Max. freqency (per channel)100 kHz
     SignalsA,B,Inx
     Signal typeopen collector, single ended
     Typeincremental
    
Digital inputs
     High voltage6 .. 30 V
     Low voltage-10 .. 5 V
     NoticeDin3 parallel with Dout1
     Number4 (Din0..3)
    
Digital outputs
     Continuous output current1.5 A
     Loadresistive, inductive
     NoticeDout1 parallel with Din3
     Number2 (Dout0..1)
     Output voltageElectronic supply voltage Ue
     Signal typepositive switching
    
Analog inputs
     Number2 (AIN0..1)
     Signal type+/- 10 V, 12 Bit, single ended
1No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
2power amplifier switched off, 5V output (sensor supply) is free
3No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
4connector cable with max. possible cable cross-section, PWM frequency 32 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 3.5 A → 2.9 Aeff, 3 A → 2.4 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
5connector cable with max. possible cable cross-section, PWM frequency 32 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 3.3 A → 2.9 Aeff, 3 A → 2.4 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
6default value
mcManual 🔒
2D/3D-Drawing 🔒
mcPLC 🔒