mcDSA-B60-Modul
| 
             Article number: 1504906 Category: Servo amplifier  | 
         Picture similar  | 
      
| 
              | 
      |
Features
- Motor controller up to 15A
 - Compact four-quadrant controller for: DC motors, BLDC motors
 - CAN interface (Protocol DS301)
 - integrated digital inputs
 - integrated analog inputs
 - Overvoltage, undervoltage and overtemperature monitoring
 - Device status notification with the help of 3 LEDs (Power, Status, Error)
 - Easily programmable due to built-in MPU (Motion Process Unit)
 
Technical data
| Name | Value | 
|---|---|
| Supply voltages | |
| - Electronic supply voltage Ue*1 | 9..30 V | 
| - Electronic current consumption@ Ue=24V*2 | typ. 20 mA | 
| - Power supply voltage Up*3 | 9..60 V | 
| Output current | |
| - Max. output current | 15 A | 
| - Continuous output current @ Up=24V*4 | 5 A | 
| - Continuous output current @ Up=48V*4 | 4.3 A | 
| PWM | |
| - Output voltage | 90% Up | 
| - PWM frequency | 12.5, 25*5 kHz | 
| - PWM mode | symmetrical | 
| Motor types | |
| - DC motors | yes | 
| - BLDC motors | yes | 
| - Linear motors | no | 
| - Stepper motors | no | 
| Mechanical | |
| - Size LxWxH | 53 x 41 x 10 mm | 
| CAN bus | |
| - Protocol | DS301 | 
| - Galvanically isolated | no | 
| Sensor supply (Hall) | |
| - Output voltage | 5 V | 
| - Max. output current | 0.2 A | 
| Hall sensors | |
| - Input voltage | 0..5 V | 
| - Signal type | open collector, single ended | 
| Digital inputs | |
| - Number - digital inputs | 4 (Din0..3) | 
| Analog inputs | |
| - Number | 2 (Ain0..1) | 
| - Signal type - Ain | 0..10 V, 12 Bit, single ended | 
Modifications and errors excepted.
*1 No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
*2 power amplifier switched off, 5V output (sensor supply) is free
*3 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V 
*4 connector cable with max. possible cable cross-section, PWM frequency 25 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 5 A → 4.1 Aeff, 4.3 A → 3.5 Aeff
    no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
*5 default value
Cross references
- mcDSA-B60
 - mcDSA-B60-Lp
 - mcDSA-B65
 - mcDSA-B65-Lp
 - mcDSA-B65-Modul
 
Devices from the same family:
Downloads
- Data sheet: mcDSA-B60-MODUL_en.pdf
 - Documentation: mcManual   

 - 2D, 3D drawings: mcDSA-B60-MODUL.zip   

 - Configuration software: mPLC Setup   

 
Accessories