mcDSA-E47-Lp
Article number: 1511157 Category: Servo amplifier |
Picture similar |
Features
- Motor controller up to 50A
- Compact four-quadrant controller for: DC motors, BLDC motors, Linear motors
- CAN interface (Protocol DS301, Device profile DS402)
- integrated digital inputs
- integrated digital outputs
- integrated analog inputs
- Overvoltage, undervoltage and overtemperature monitoring
- Device status notification with the help of 3 LEDs (Power, Status, Error)
- Hex switches to set the device node id
- Easily programmable due to built-in MPU (Motion Process Unit)
Technical data
Name | Value |
---|---|
Supply voltages | |
- Electronic supply voltage Ue*1 | 9..30 V |
- Electronic current consumption@ Ue=24V*2 | typ. 60 mA |
- Power supply voltage Up*3 | 9..60 V |
Output current | |
- Max. output current | 50 A |
- Continuous output current @ Up=24V*4 | 10 A |
- Continuous output current @ Up=48V*4 | 8.5 A |
PWM | |
- Output voltage | 100% Up |
- PWM frequency | 25, 32*5, 50 kHz |
- PWM mode | symmetrical / asymmetrical |
Motor types | |
- DC motors | yes |
- BLDC motors | yes |
- Linear motors | yes |
- Stepper motors | no |
Mechanical | |
- Size LxWxH | 97 x 73 x 14 mm |
CAN bus | |
- Protocol | DS301 |
- Device profile | DS402 |
- Galvanically isolated | no |
Sensor supply (Encoder) | |
- Output voltage | 5 V |
- Max. output current | 0.2 A |
Encoder | |
- Type | sin / cos |
- Input voltage | 1 V peak-peak, differential |
- Signal type | sine/cosine, analog, differential |
Digital inputs | |
- Number - digital inputs | 7 (Din0..6) |
Digital outputs | |
- Number | 2 (Dout0..1) |
- Continuous output current | 1.5 A |
Analog inputs | |
- Number | 2 (Ain0..1) |
- Signal type - Ain0 | +/- 10 V, 12 Bit, differential |
- Signal type - Ain1 | +/- 10 V, 12 Bit, single ended |
Modifications and errors excepted.
*1 No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
*2 power amplifier switched off, 5V output (sensor supply) is free
*3 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
*4 connector cable with max. possible cable cross-section, PWM frequency 32 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 10 A → 8.2 Aeff, 8.5 A → 6.9 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
*5 default value
Cross references
- mcDSA-E40
- mcDSA-E40-EtherCAT
- mcDSA-E40-EtherCAT-HC
- mcDSA-E40-HC
- mcDSA-E40-Lp
- mcDSA-E40-Modul
- mcDSA-E42
- mcDSA-E42-HC
- mcDSA-E42-Lp
- mcDSA-E42-Modul
- mcDSA-E45
- mcDSA-E45-EtherCAT
- mcDSA-E45-EtherCAT-HC
- mcDSA-E45-HC
- mcDSA-E45-Lp
- mcDSA-E45-Modul
- mcDSA-E45-PROFINET-HC
- mcDSA-E45-PROFINET
- mcDSA-E47
- mcDSA-E47-EtherCAT
- mcDSA-E47-EtherCAT-HC
- mcDSA-E47-HC
- mcDSA-E47-Modul
- mcDSA-E47-PROFINET
- mcDSA-E47-PROFINET-HC
Devices from the same family:
Downloads
- Data sheet: mcDSA-E47-Lp_en.pdf
- Documentation: mcManual
- 2D, 3D drawings: mcDSA-E47-Lp.zip
- Configuration software: mPLC Setup
Accessories
- Connectors: Connector Set_mcDSA-E47-Lp