mcDSA-S45-HC
|
Article number: 1511178 Category: Servo amplifier |
Picture similar |
|
|
|
Features
- Motor controller up to 20A
- Compact four-quadrant controller for: Stepper motors
- CAN interface (Protocol DS301, Device profile DS402)
- integrated digital inputs
- integrated digital outputs
- integrated analog inputs
- Overvoltage, undervoltage and overtemperature monitoring
- Device status notification with the help of 3 LEDs (Power, Status, Error)
- Hex switches to set the device node id
- Easily programmable due to built-in MPU (Motion Process Unit)
Technical data
| Name | Value |
|---|---|
| Supply voltages | |
| - Electronic supply voltage Ue*1 | 9..30 V |
| - Electronic current consumption@ Ue=24V*2 | typ. 60 mA |
| - Power supply voltage Up*3 | 9..60 V |
| Output current | |
| - Max. output current | 20 A |
| - Continuous output current @ Up=24V*4 | 10 A |
| - Continuous output current @ Up=48V*4 | 9 A |
| PWM | |
| - Output voltage | 85% Up |
| - PWM frequency | 32 kHz |
| - PWM mode | symmetrical |
| Motor types | |
| - DC motors | no |
| - BLDC motors | no |
| - Linear motors | no |
| - Stepper motors | yes |
| Mechanical | |
| - Size LxWxH (HC Version) | 110 x 39 x 77 mm |
| CAN bus | |
| - Protocol | DS301 |
| - Device profile | DS402 |
| - Galvanically isolated | no |
| Sensor supply (Encoder) | |
| - Output voltage | 5 V |
| - Max. output current | 0.2 A |
| Incremental encoder | |
| - Type | incremental |
| - Input voltage (24V tolerant) | 0..5 V |
| - Signal type | differential, open collector, single ended |
| Digital inputs | |
| - Number - digital inputs | 8 (Din0..7) |
| Digital outputs | |
| - Number | 2 (Dout0..1) |
| - Continuous output current | 1.5 A |
| Analog inputs | |
| - Number | 2 (Ain0..1) |
| - Signal type - Ain0 | +/- 10 V, 12 Bit, differential |
| - Signal type - Ain1 | +/- 10 V, 12 Bit, single ended |
Modifications and errors excepted.
*1 No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
*2 power amplifier switched off, 5V output (sensor supply) is free
*3 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
*4 connector cable with max. possible cable cross-section, PWM frequency 32 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 10 A → 8.1 Aeff, 9 A → 7.3 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
Cross references
- mcDSA-S40
- mcDSA-S40-HC
- mcDSA-S40-Modul
- mcDSA-S45
- mcDSA-S45-Modul
Devices from the same family:
Downloads
- Data sheet: mcDSA-S45-HC_en.pdf
- Documentation: mcManual

- 2D, 3D drawings: mcDSA-S45-HC.zip

- Configuration software: mPLC Setup

Accessories
- Connectors: Connector Set_mcDSA-S45-HC
Document Actions