mcER-L40
Article number: 1514321 Category: Brake chopper Certification: UL *1 |
Picture similar |
Features
- integrated digital outputs
- Short circuit and overtemperature monitoring
- Device status notification with the help of 3 LEDs (Power, Status, Error)
- Hex switches to set at which voltage the resistor should dissipate energy
Technical data
Name | Value |
---|---|
Power | |
- Electronic supply voltage Up*2 | 18..60 V |
- Max. braking peak current @ Ubr=60V
(certified UL)*3 |
55 A |
- Max. braking continuous current @ Ta=40°C
(certified UL)*3 |
10 A |
Braking resistor | |
- Adjustable braking voltage Ubr | 18..60 V |
- Braking resistor @ Ubr=60V | min. 1 Ohm (external) |
Mechanical | |
- Size LxWxH | 110 x 23 x 77 mm |
Digital output | |
- Number | 1 (/Error) |
Modifications and errors excepted.
*1 The certified performance data must be observed (see UL Instruction Note)
*2 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
*3 permitted current depends on the used braking resistor (maximum value refers to the smallest possible resistance - 1 Ohm)
Cross references
- mcER-L40-Lp
- mcER-L42
- mcER-L60-30-Lp
- mcER-L60-30-Modul
- mcER-L60-30
- mcER-L60-53
- mcER-L60-60-Lp
- mcER-L60-60-Modul
- mcER-L60-60
Devices from the same family:
Downloads
- Data sheet: mcER-L40_en.pdf
- Documentation: mcManual
- 2D, 3D drawings: mcER-L40-UL.zip
- Configuration software: mPLC Setup
- Instruction note: InstructionNote_mcER-L40
Accessories
- Connectors: Connector Set_mcER-L40
Document Actions