mcER-L60-30-Lp
| 
             Article number: 1515422 Category: Brake chopper Certification: UL *1  | 
         Picture similar  | 
      
| 
              | 
      |
Features
- integrated digital outputs
 - Short circuit and overtemperature monitoring
 - Device status notification with the help of 3 LEDs (Power, Status, Error)
 
Technical data
| Name | Value | 
|---|---|
| Power | |
| - Electronic supply voltage Up*2 | 18..60 V | 
| - Max. braking peak current (certified UL)*3 | 60 A @ 60 V | 
| - Max. braking continuous current (certified UL)*3 | 5 A | 
| - On-Time / Off-Time (certified UL)*3 | approx. 1 s / 90 s @ 60 A | 
| Braking resistor | |
| - Braking voltage UBr | 30 V | 
| - Braking resistor | min. 1 Ohm (external) | 
| Mechanical | |
| - Size LxWxH | 53 x 41 x 11 mm | 
| Digital output | |
| - Number | 1 (/Error) | 
Modifications and errors excepted.
*1 The certified performance data must be observed (see UL Instruction Note)
*2 No reverse polarity protection, the destruction limit is at overvoltage of >= 100V 
*3 ambient temperature 55 °C
Cross references
- mcER-L40-Lp
 - mcER-L40
 - mcER-L42
 - mcER-L60-30-Modul
 - mcER-L60-30
 - mcER-L60-53
 - mcER-L60-60-Lp
 - mcER-L60-60-Modul
 - mcER-L60-60
 
Devices from the same family:
Downloads
- Data sheet: mcER-L60-30-Lp_en.pdf
 - Documentation: mcManual   

 - 2D, 3D drawings: mcER-L60-30-Lp-UL.zip   

 - Configuration software: mPLC Setup   

 - Instruction note: InstructionNote_mcER-L60-xx-LP
 
Accessories
- Connectors: Connector Set_mcER-L60-30-Lp
 
Document Actions