mcDSA-E25
Article number: 1511110 Category: Servo amplifier |
Picture similar |
Features
- Motor controller up to 100A
- Compact four-quadrant controller for: DC motors, BLDC motors, Linear motors
- CAN interface (Protocol DS301, Device profile DS402)
- integrated digital inputs
- integrated digital outputs
- integrated analog inputs
- Overvoltage, undervoltage and overtemperature monitoring
- Device status notification with the help of 3 LEDs (Power, Status, Error)
- Hex switches to set the device node id
- Easily programmable due to built-in MPU (Motion Process Unit)
Technical data
Name | Value |
---|---|
Supply voltages | |
- Electronic supply voltage Ue*1 | 9..30 V |
- Electronic current consumption@ Ue=24V*2 | typ. 70 mA |
- Power supply voltage Up*3 | 9..60 V |
Output current | |
- Max. output current | 100 A |
- Continuous output current @ Up=24V*4 | 35 A |
- Continuous output current @ Up=48V*4 | 26 A |
PWM | |
- Output voltage | 100% Up |
- PWM frequency | 25, 32*5, 50 kHz |
- PWM mode | symmetrical / asymmetrical |
Motor types | |
- DC motors | yes |
- BLDC motors | yes |
- Linear motors | yes |
- Stepper motors | no |
Mechanical | |
- Size LxWxH | 111 x 100 x 31 mm |
CAN bus | |
- Protocol | DS301 |
- Device profile | DS402 |
- Galvanically isolated | yes |
Sensor supply (Encoder/Hall) | |
- Output voltage | 5 V |
- Max. output current | 0.2 A |
Incremental encoder | |
- Type | incremental |
- Input voltage (24V tolerant) | 0..5 V |
- Signal type | differential, open collector, single ended |
Hall sensors | |
- Input voltage (24V tolerant) | 0..5 V |
- Signal type | differential, open collector, single ended |
Digital inputs | |
- Number - digital inputs | 8 (Din0..7) |
Digital outputs | |
- Number | 2 (Dout0..1) |
- Continuous output current | 1.5 A |
Analog inputs | |
- Number | 2 (Ain0..1) |
- Signal type - Ain0 | +/- 10 V, 12 Bit, differential |
- Signal type - Ain1 | +/- 10 V, 12 Bit, single ended |
Modifications and errors excepted.
*1 No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
*2 power amplifier switched off, 5V output (sensor supply) is free
*3 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
*4 connector cable with max. possible cable cross-section, PWM frequency 25 kHz, ambient temperature 40 °C (t >40 °C derating), RMS current: 35 A → 28.5 Aeff, 26 A → 21.2 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
*5 default value
Cross references
- mcDSA-E20
- mcDSA-E20-EtherCAT
- mcDSA-E20XC
- mcDSA-E20XC-EtherCAT
- mcDSA-E22
- mcDSA-E22XC
- mcDSA-E22XC-EtherCAT
- mcDSA-E25-EtherCAT
- mcDSA-E25XC
- mcDSA-E25XC-EtherCAT
- mcDSA-E25XC-PROFINET
- mcDSA-E25XC-SSI
- mcDSA-E27
- mcDSA-E27-EtherCAT
- mcDSA-E27XC
- mcDSA-E27XC-EtherCAT
- mcDSA-E27XC-PROFINET
- mcDSA-E27XC-SSI
Devices from the same family:
Downloads
- Data sheet: mcDSA-E25_en.pdf
- Documentation: mcManual
- 2D, 3D drawings: mcDSA-E25.zip
- Configuration software: mPLC Setup
Accessories
- Connectors: Connector Set_mcDSA-E25
Document Actions